PLATON II
- Features
-
- Improved screening performance
- Easier maintenance
- Developed easy to handle by an Auto -tuning function.
| Model | KP-5000AT |
|---|---|
| Process capacity*1 | 400 to 1000 kg/hr |
| Sensing system | Line sensor camera x 2 +RGB color filter |
| Camera pixels | 5150 |
| Reject ejection | High-speed air valves x 20 |
| Light source | Fluorescent lamps x 4, LED backlight |
| Accuracy*2 | 99% |
| Material flow adjustment mechanism |
Vibration feeder |
| Material alignment mechanism |
Flat chute |
| Operation panel | Color liquid crystal touch panel |
| Outside dimensions |
515 (W) x 995 (D) x 1485 to 1600 (H) |
| Weight | Approx. 180 kg |
| Power requirements |
120 V AC/ 220V AC |
| Electric power consumption |
240 W |
| Compressed air consumption*3 |
300 (0.45 MPa) NL/min |
| Operating temperature range |
0 to 40ºC |
| Camera resolution | 0.05 mm |
*1 Max. throughput varies depending on characteristics, shapes and concentration of contaminants.
*2 Indicates the separation accuracy when the ratio of different-colored pellets (red or black) mixed into natural-colored pellets (milk-white or white) is less than 0.1%.
*3 Air supply in a compressor needs 350 ( 0.6 MPa)L/min .